Electronic products enter Australia, in addition to security marks, there should be a EMC sign, that is, the c-tick sign. The purpose is to protect the resources of radio communication band. Its implementation system is somewhat similar to the European EMC directive. Therefore, it can be self declaration by producers / importers. However, before applying for the C-tick sign, it must be tested according to the relevant CISPR standards. It should be endorsed by the Australian importer & submit the report. Australia ACA (Australian Commication Authority) is accepted, and the registration number is issued.


Australia, the EMC requirements for electrical products are monitored by ACA (Australin Communications Authority). In addition to the standards of Australia and New Zealand (AS/NZS), there were 103 other standards recognized in ACA2002, including EN, IEC and CISPR.


In order to limit the influence of electromagnetic interference, Australia has imposed electromagnetic interference (EMI) mandatory requirements for all products in the standard range since January 1999. Part of the EMC experiment projects must comply with the mandatory requirements, they are: conduction interference, intermittent interference (clicks), radiation interference. The remaining EMC projects are not mandatory. The product can be attached to the C-Tick mark if the product is tested in accordance with the relevant standards. If any company or individual wants to use this sign, it must apply to the competent authorities of the government, get the written approval, and use it, and the height of the logo should not be less than 3 millimeters.


The information of Australian suppliers must be marked on the side of the C-Tick logo, so that ACA can be traced back to the supplier responsible for the product EMC when sampling products in the market. The identification of information includes four aspects:

1. the name and address of the Australian supplier.

2. Australian Corporation registration number (Australian Company Number)

3. the number of Australian suppliers issued by ACA.

4. the Australian registered trademark used in the Australian market.


The EMC system in Australia divides the product into three levels. Suppliers must register at ACA before applying for sale level two and level three products, and apply for the use of C-Tick logo.


Level one product refers to products that interfere with the use of wireless spectrum equipment, such as manual switches, simple relays, one-way squirrel cage induction motors, resistors and so on. For the level one product, the supplier must sign the compliance statement and provide the product description. The first level product can voluntarily apply for the C-Tick logo, but when the supplier chooses the logo, it will provide conformance statement and product description while providing a conformance record to prove that the product described in the statement has met the relevant EMC standard. The test site is not required and the internal test is allowed.


Level two product refers to products that are highly radiated by devices that use wireless spectrum, such as switching power supply, electric welder, dimmer, and most household appliances. In addition to signing the declaration of conformity and providing product description, suppliers should also provide test reports according to the relevant standards. If there is no relevant standard, they need to provide technical structure files, where the test sites do not require and allow internal testing.


Level three product refers to products that use wireless spectrum devices with high interference radiation, that is, CISPR11 and CISPR22. At present, the communication terminal products are still included in this area, but from November 7, 2003, the terminal products will be divided into two products. In addition to signing conformance declarations and providing product descriptions, suppliers are required to provide test reports issued by accredited testing institutions. At the same time, we should also issue a certificate of quality management system issued by the QSM certification authority.


4.jpg


Australia ACMA in March 1, 2013 the implementation of a single regulatory compliance mark RCM, according to the Australian Communications and Media Authority (Australian Communications And Media Authority, ACMA) the latest news, Australia three existing conformity mark (C-Tick, A-Tick and RCM) will be merged into a single compliance mark RCM. It also means that a product in the future will meet all relevant regulations and requirements of ACMA, such as telecommunications, radio communication, EMC, EMC and electronic and electrical equipment safety requirements of Australia and New Zealand and its states and SEZ. At that time, the C-Tick and A-Tick conformance signs will no longer be used. In order to register the product for the supplier, ACMA will establish a new version of the data system, and the label notifications will no longer require the information requirements of the vendor's identity.


This is to match the new Australian new electrical equipment safety system (EESS), which is to be implemented in March 1, 2013. The system covers the electrical equipment safety requirements of Australia and New Zealand and its states and SEZ. RCM will become a single regulatory compliance mark under the new electrical safety system EESS. For details, see the web site of the ERAC.


Since March 1, 2013, the new system applies to newly registered suppliers, that is, those who have not yet registered with the ACMA supplier data system. After the 3 year transition period, that is, from March 1, 2016, the new system will apply to all suppliers.


From March 1, 2013, the newly registered suppliers must register on the new database, and use RCM as a single conformance mark, which indicates that all the relevant regulations and requirements of ACMA conform to the requirements.


For registered in the ACMA database in March 1, 2013 before the supplier, has 3 years of the transition period, the new version of the database on the registration and use the RCM logo. That is to say, before the transition period (March 1, 2016), the C-Tick or A-Tick logo can still be used for its products. In addition, before the transition period, the products that have met the requirements of the existing regulations and have C-Tick or A-Tick signs are not required to reattach the label, and the market can be circulated. After March 1, 2016, all the suppliers that need to attach the certification mark on the product must register and use the RCM logo on the new database.


RCM signs should be marked when the product meets the requirements of both ACMA and EESS. The introduction of the RCM sign does not affect the compliance of the equipment to the relevant regulations. The inspection, record preservation and evidence requirements will be stipulated in the relevant label notices.


Copyright © 深圳市深测检测技术服务有限公司     粤ICP备10205799号Technical support:SZTDWL